To say that Edge computing is growing in popularity is a pretty big understatement. In fact, according to Gartner, by 2025 75% of all enterprise-generated data will be created and processed outside the traditional data center or cloud. Low latency is the primary driver for this surge, but there are also others, like impressive cost savings and bandwidth optimization.
Is it simple to bring computing to The Edge? Yes. But there are nonetheless several opportunities to make costly mistakes, and this post shines a light on three of the most important to avoid when planning your deployment.
Before we get into the factors, though, we need to define where The Edge installation is. We have all heard of the Edge Data Center, an installation at the edge of a network but installed in a more traditional IT space – like a data center, but usually on a smaller scale. For this kind of installation, plan as if you are going into a data center...because you are.
Now, move out past the Edge Data Center to a more remote installation; you’re still at The Edge, but a better term might be Spine Data Center. This kind of deployment can be in a more traditional IT space, but could also be more remote, maybe a container or similar pre-engineered solution. And out there, the factors discussed below become more relevant.
Finally, let’s go all the way out to The Edge – from one to a few (less than 10) standalone footprints in any location that is not a traditional IT space. You can call it an Edge Data Center, but clearly the issues discussed below are critical to a successful, stable, and secure installation.
Please keep these general definitions in mind, with the following rule: The further you get from a traditional IT space, the more important the three following factors become.
It’s true what they say: “When you fail to prepare you prepare to fail.” Without a thoughtful assessment of your needs and the location of the deployment, you could end up with a one that’s compromised from the get-go. Among the factors you need to consider are:
Edge systems are often located in environments in which temperature and air flow change by the minute (think an oil rig or wind turbine farm), making the enclosure the primary defense against the elements and contaminants. Without a well-engineered enclosure, data – and entire networks – are at risk.
Often Edge deployments are placed in rooms that weren’t designed to deliver cooling appropriate for the heat generated by IT equipment. And even if in a “typical” IT space, there still may not be enough heat removal capacity to support additional IT loads. In some cases, facility personnel may be certain that the existing air conditioning (called a “comfort cooling” system) will do the job of removing adequate heat from the room. Wrong. Comfort cooling systems are neither powerful enough to cool the equipment, nor do they account for the specific air flow and moisture removal required.
Here are some additional risks of relying on a facility’s AC system:
Solving for location challenges, ensuring reliable power, maintaining the best climate for the equipment, and properly securing the investment...all of these Edge-related needs can be satisfied with the right IT cabinet. Today’s best-in-class are designed for the unique conditions found in many Edge data centers, and with the future in mind. When it’s time to plan your system, work with a partner that can apply experience to ensure that you get the most out of the system, and that can identify a product solution that makes maintaining and leveraging that system simple and effective.
Read more about Edge and how to design a system that will improve business performance by downloading our Edge Infrastructure Handbook.